iX30 – Connections

Knowledge Base - Sirius iX30
28/05/2020
Print

*The Sirius iX30 accepts a power between 5.0 and 16.0 VDC. A higher input voltage results in lower power consumption and ensuring cost-efficient wiring with a smaller conductor diameter. When using an external power supply, it must comply with SELV guidelines.

Advised to power the reader with a power supply that can supply a minimum of 5W to a maximum of 15W. If the reader is powered by a power supply with a power higher than 15W, a fuse of 500mA must be placed by the installer.

DIP Switch-1 is used to determine the RS485 resistance.